Megapower Elect. provides electric motor repair and rewinding services for AC motors. Services can include winding inspection, stator rewinding, insulation checks and related mechanical repairs, depending on the motor type.
When performed strictly according to standards (such as IEC 60034-23), a quality rewind preserves efficiency within ±0.2%.
Poorly executed or unstandardized workshop rewinds can cause efficiency to drop by 1% to 5%.
Cost Benchmark: If the repair cost exceeds 60% of the price of a new replacement motor, replacing is typically more economical.
When to Rewind: Recommended for motors under 10 years old with a single failure event, custom or obsolete models, or large/industrial motors where buying new is very expensive.
When to Replace: Recommended for motors with complete visible charring/burnout, units experiencing their second winding failure within 3 years, or small standard motors where a new unit costs about the same as labor.
- Low or no water pressure
- Unusual grinding, humming, or squealing noises (often from worn bearings)
- Continuous running or failure to start
- Circuit breaker tripping or electrical burning smell
- Visible water leaks or rust around the pump housing and seals
- Inspection & Testing: Electrical and mechanical testing to confirm the fault.
- Data Recording: Logging original turns, coil pitch, wire size, and connection layout before stripping.
- Stripping & Cleaning: Removing old copper coils and insulation, then cleaning and polishing the stator slots.
- Rewinding: Installing fresh slot insulation and winding new copper coils to original specifications.
- Varnishing & Curing: Impregnating the winding with insulating varnish and baking it in an oven to seal and secure the coils.
- Mechanical Repair: Replacing worn bearings, seals, or repairing shafts if needed.
- Final Testing: Performing resistance, insulation resistance, and load tests.